XHHW / PVC POWER CABLE

StumbleUponEmail

Description

  • 600 Volts
  • Copper Conductors
  • XLP Insulated Singles Rated XHHW (or XLPTC)
  • Non-Shielded Tray Cable
  • Available in 3 or 4 Conductors with Ground
  • Overall PVC Jacket
  • Flame Retardant, Moisture and Sunlight-Resistant

APPLICATIONS

  • Pro-Line’s Type TC Power Cable is used to supply power to motors, or for connection to other power devices in industrial settings
  • Primary installations include cable trays, raceways, and outdoor locations where supported by a messenger wire
  • Type TC Power Cable is listed for direct burial and for use in Class 1, Division 2 hazardous locations and Class 1 control circuits
  • This cable may be used in wet or dry locations at temperatures not to exceed 90°C. 6 and 8 AWG constructions with insulated grounds (standard) and 4 AWG and larger with bare or insulated ground are UL Listed for exposed runs (ER) per NEC 336.10

 

STANDARDS AND REFERENCES

Pro-Line’s Type TC Power Cable meets or exceeds the applicable requirements of the
following standards and specifications:
  • ASTM – (All applicable standards)
  • UL 1277 – Electrical Power and Control Tray Cables
  • UL 1581 – Electrical Wires, Cables and Flexible Cords
  • ICEA S-58-679 – Control Cable Conductor Identification. (Method 4 – single color (black) compounds with surface printing of numbers)
  • UL 1685 – UL Flame Exposure Test (70,000 BTU/hr)
  • ICEA T-29-520 – Vertical Cable Tray Flame Test (210,000 Btu/hr)
  • IEEE 1202 – Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies (70,000 BTU/hr)

Pro-Line’s Type TC Power Cable meets and exceeds all construction requirements of ICEA S-95-658 (NEMA WC 70) – Nonshielded 0 – 2 kV Cables, with testing frequencies based on UL requirements.

CONSTRUCTION

Pro-Line’s Type TC Power Cable is available in sizes 8 AWG through 750 kcmil and is manufactured using Type XHHW-2 conductors. Individual conductors are bare annealed copper covered with a cross-linked polyethylene (XLP) insulation. The overall jacket consists of a flame retardant, moisture and sunlight resistant PVC jacket. TC Power Cable shall be PRO-LINE WIRE & CABLE or approved equal.

  • Sizes 8 thru 2 AWG: Concentric, compressed or compact stranding, class B (7 strands) per ASTM B-8
  • Sizes 1 thru 4/0 AWG: Concentric, compressed or compact stranding, class B (19 strands) per ASTM B-8
  • Sizes 250 thru 500 KCMIL: Concentric, compressed or compact stranding, class B (37 strands) per ASTM B-8
  • Size 750 KCMIL: Concentric, compressed or compact stranding, class B (61 strands) per ASTM B-8

WEIGHTS, MEASUREMENTS AND PACKAGING

45